Skip to content

CyclingCharger guides

Di2 Charging Stops When E-TUBE Connects: RD-R8150 Checks

CyclingCharger editorial team · Updated 20 November 2026

On RD-R8150, an E-TUBE PROJECT connection can interrupt charging. The user manual says to disconnect E-TUBE PROJECT and reconnect the charging cable afterwards. It also warns that the rear derailleur does not shift gears while connected over Bluetooth LE.

Separate three operating states

RD-R8150 conditions that can make a normal system look unresponsive
Current state What to expect Next check
Charging cable connected Front and rear shifting are unavailable during charging. Complete the charge and disconnect before testing shifting.
E-TUBE PROJECT connected while charging Charging stops according to the user manual. End the app connection, then reconnect the correct charging cable.
Bluetooth LE app session still connected Normal rear shifting is not available in that connection state. Cancel the connection from the phone/tablet when finished.

A controlled return to charging

  1. Check that no software update or other operation is still running. Complete the application's instructions; do not interrupt an update just to follow a charging checklist.
  2. When the app task is finished, disconnect the E-TUBE Bluetooth session from the phone or tablet as the manual describes.
  3. In a suitable dry indoor location, reconnect the dedicated cable to the correct port and compliant power source.
  4. Observe the actual charging indication. On RD-R8150 it starts blue and goes out when complete; flashing red leads to the manual's troubleshooting steps.
  5. Disconnect the charge cable and make the ordinary stationary shifting check after the app connection is closed.

Keep a repeatable fault report

Record the phone/app state, cable connection and LED at the moment charging stopped. “Charging stopped as the app connected, restarted after disconnecting and reconnecting the lead” is different evidence from “no charging light with the phone disconnected”. Do not buy another charger until those states are separated.

This is not a firmware-recovery procedure and does not establish compatibility for every E-TUBE version or Di2 generation. For older phone discovery, use the EW-WU111 guide. For a continuing charge fault, return to the symptom checklist.

Sources and scope

Checked 20 November 2026. Model-specific instructions take priority over a general guide. This article is not a report of independent compatibility or battery testing.